CABLE REQUEST FORM
CABLE REQUEST FORM
PRODUCTS

M2XSH

SHARE

Product Certificates

You can click to download our certificates.

Areas of Use

Used as fixed installation cable in marine vehicles. Screening layer forms a shield for protection against electromagnetic interferences. Halogen-Free and Flame Retardant construction ensures non-corrosive and highly visible environment during a fire.

Cable Construction

  • Conductor Stranded Annealed Copper (IEC/EN 60228, Class 2) (tinned copper and/or Class 5 versions are available upon request)
  • Insulation XLPE (IEC 60092-360)
  • Core Colors According to HD 308 S2 (# of Cores ≥5 => White numbered)
  • Lay-up Cores are stranded in layers
  • Inner Sheath HFFR
  • Armour Galvanised Steel Wire Braid
  • Outer Sheath HFFR (IEC 60092-360 SHF1), RAL 9005 - Black or RAL 7001 - Grey
  • Reference Standards IEC 60092-353

Technical Properties

  • Operating Voltage 0.6/1 (1.2) kV
  • Test Voltage 3.5 kV (a.c.) 8.4 kV (d.c)
  • Conductor Resistance IEC/EN 60228
  • Insulation Resistance >5000 M.Ωxkm
  • Temperature Range -40 °C........+90 °C
  • Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
  • Smoke Density IEC/EN 61034-1+2
  • Amount of Halogen Acid Gas IEC/EN 60754-1
  • Corrosive Gases Measurement IEC/EN 60754-2
  • Min. Bending Radius (Fixed) 8 x Cable Diameter

Footnote

The name of this product is TFCI 0.6/1 (1.2) kV according to ABS.