Multiple-conductor cable using non-integral jacket. These double screened cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or the communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects

Cable Construction

  • Conductor Stranded Annealed Tinned Copper (ASTM B-33)
  • Insulation PVC (80°C) UL 1581
  • Core Colors Can be manufactured according to the customer’s request
  • Insulated Conductors AWG16 & AWG22 Style 1095
  • Lay-up Cores are stranded in layers
  • Separator PET Foil
  • Outer Sheath PVC Jacket (UL 1581 Class 80°C). The thickness of the overall jacket is in accordance with the UL 758.
  • Reference Standards UL Style 1095, UL 758

Technical Properties

  • Operating Voltage 300 V
  • Test Voltage 2 kV
  • Conductor Resistance UL 1581 - Section 220
  • Max. Operating Temperature Fixed: -30°C … +80°C / Flexible: -5°C … +50°C
  • Flame Retardancy FT2 Horizontal Flame Test (UL 2556), VW-1 Flame Test (UL 2556), IEC/EN 60332-1
  • Conductor Corrosion UL 2556
  • Deformation Resistance UL 2556
  • Min. Bending Radius (Fixed) 8 x Cable Diameter