CABLE REQUEST FORM
CABLE REQUEST FORM
PRODUCTS

FMGCH FE180

SHARE

Product Certificates

You can click to download our certificates.

Areas of Use

Used for communication and instrumentation purpose in electronic systems of marine vehicles. Screening layer protects the transmitting signal against electromagnetic interferences. Halogen-Free and Flame Retardant construction ensure non-corrosive and highly visible environment during a fire. Also, min.180 minutes of circuit integrity under fire conditions is achieved by its special design.

Cable Construction

  • Conductor Stranded Annealed Tinned Copper (IEC 60228, Class 2)
  • Flame Barrier Mica Tape
  • Insulation HEPR (IEC 60092-360)
  • Core Colors Pair: Black / White, Numbered Quad: Black / White / Red / Blue, Numbered
  • Lay-up Cores are twisted as pairs and pairs are stranded in layers
  • Separator PET Foil (HFFR filler upon request)
  • Overall Screen Annealed Copper Wire Braiding (90% Coverage)
  • Outer Sheath HFFR (IEC 60092-360 SHF1), RAL 6018 - Green
  • Reference Standards IEC 60092-376

Technical Properties

  • Operating Voltage 150/250 (300) V
  • Test Voltage 1.5 kV (a.c) 3.6 kV (d.c)
  • Conductor Resistance IEC/EN 60228
  • Insulation Resistance >5000 M.Ωxkm
  • Temperature Range -40 °C........+90 °C
  • Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
  • Fire Resistance IEC 60331-21
  • Smoke Density IEC/EN 61034-1+2
  • Amount of Halogen Acid Gas IEC/EN 60754-1
  • Corrosive Gases Measurement IEC/EN 60754-2
  • Min. Bending Radius (Fixed) 8 x Cable Diameter