CABLE REQUEST FORM
CABLE REQUEST FORM
PRODUCTS

FM2XH FE180

SHARE

Product Certificates

You can click to download our certificates.

Areas of Use

Used as fixed installation cable in marine vehicles, Halogen Free and Flame Retardant construction ensures non- corrosive and highly visible environment during fire. In addition, min.180 minutes of circuit integrity under fire conditions is achieved by its special design. 

Cable Construction

  • Conductor Stranded Annealed Copper (IEC/EN 60228, Class 2) (tinned copper and/or Class 5 versions are available upon request)
  • Flame Barrier Mica Tape
  • Insulation XLPE (IEC 60092-360)
  • Core Colors Pair: Black / White, Numbered Quad: Black / White / Red / Blue, Numbered
  • Lay-up Cores are stranded in layers
  • Separator PET Foil (HFFR filler upon request)
  • Outer Sheath HFFR (IEC 60092-360 SHF1), RAL 6018 - Green
  • Reference Standards IEC 60092-376

Technical Properties

  • Operating Voltage 150/250 (300) V
  • Test Voltage 1.5 kV (a.c) 3.6 kV (d.c)
  • Conductor Resistance IEC/EN 60228
  • Insulation Resistance >5000 M.Ωxkm
  • Temperature Range -40 °C........+90 °C
  • Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
  • Fire Resistance IEC 60331-21
  • Smoke Density IEC/EN 61034-1+2
  • Amount of Halogen Acid Gas IEC/EN 60754-1
  • Corrosive Gases Measurement IEC/EN 60754-2
  • Min. Bending Radius (Fixed) 8 x Cable Diameter

Footnote

The name of this product is FireKab BFXI FE180 150/250 (300) V according to ABS.