HMWPE cable is electrically connected (directly or indirectly) to the negative output terminal of a cathodic protection power supply. This includes bond cables to a cathodically protected structure. CP Cable is used as direct earth burial DC feeder cable in cathodic protection systems.

Cable Construction

  • Conductor Stranded Annealed Copper (IEC/EN 60228, Class 2)
  • Insulation High Molecular Weight Polyethylene (Black) Acc. to ASTM D1248 Type 3, Class C, Category 5, IEC 60502, ST7
  • Reference Standards 17-SAMSS-017

Technical Properties

  • Operating Voltage 0.6/1 kV
  • Test Voltage 3.5 kV
  • Temperature Range Operation: -30°C...+90°C, Installation: -5°C...+70°C
  • Conductor Resistance IEC/EN 60228
  • Min. Bending Radius 7.5 x Cable Diameter

Footnote

*Out of 17-SAMSS-017 scope, based on 17-SAMSS-017