LIHH-TP

SHARE

Product Certificates

You can click to download our certificates.

Areas of Use

LIHH-TP cables are used in the industrial applications for signal transmission. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. LIHH-TP cables have HFFR material in their construction and These don't burn easily and the flames go off by themselves. These have low smoke density and These don't emit poisonous and corrosive gases during the fire. These used in buildings where there are important goods or human population.

Cable Construction

  • Conductor Stranded Annealed Copper (IEC/EN 60228, Class 5, 0.34 mm²: Class 2)
  • Insulation HFFR (EN 50290-2-26)
  • Core Colors DIN 47100
  • Lay-up Cores are twisted as pairs and pairs are stranded in layers
  • Outer Sheath HFFR (EN 50290-2-27), RAL 7001 - Grey
  • Reference Standards VDE 0812, TS 13755

Technical Properties

  • Operating Voltage 0.14 mm²..0.25 mm² 250 V; 0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V
  • Test Voltage 0.14 mm² - 800 V; 0.22 mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V
  • Conductor Resistance 0.14 mm²- ≤138 Ω/km; 0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km; 0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50 mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km
  • Insulation Resistance >200 M.Ωxkm
  • Capacitance (@800Hz) Core - Core: 0.14 mm²-≤80 nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00 mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km
  • Indutance (approx.) 0.65 mH/km
  • Temperature Range Fixed: -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C
  • Flame Retardancy IEC/EN 60332-1
  • Smoke Density IEC/EN 61034-2
  • Amount of Halogen Acid Gas IEC/EN 60754-1
  • Corrosive Gases Measurement IEC/EN 60754-2
  • Min. Bending Radius Fixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter

Cross Section

  • Configuration / Cross-Section (mm/mm²) Cable Diameter (mm) (± 5%) Copper Weight (kg / km) ~ Cable Weight (kg / km)
  • 2x2x0.22 5.1 8 31
  • 3x2x0.22 5.5 13 41
  • 4x2x0.22 6.1 17 51
  • 5x2x0.22 6.8 21 63
  • 6x2x0.22 7.5 25 75
  • 7x2x0.22 7.5 29 82
  • 8x2x0.22 8.2 34 95
  • 10x2x0.22 9.8 42 123
  • 2x2x0.25 5.4 9 35
  • 3x2x0.25 5.8 14 44
  • 4x2x0.25 6.4 19 55
  • 5x2x0.25 7.1 24 68
  • 6x2x0.25 7.8 28 81
  • 7x2x0.25 7.8 33 89
  • 8x2x0.25 8.6 38 105
  • 10x2x0.25 10.3 47 135
  • 2x2x0.34 5.7 13 40
  • 3x2x0.34 6.2 20 53
  • 4x2x0.34 6.8 26 68
  • 5x2x0.34 7.6 33 83
  • 6x2x0.34 8.3 39 99
  • 7x2x0.34 8.3 46 109
  • 8x2x0.34 9.1 53 125
  • 10x2x0.34 11.0 66 164
  • 2x2x0.5 7.0 17 57
  • 3x2x0.5 7.6 26 76
  • 4x2x0.5 8.4 35 96
  • 5x2x0.5 9.4 43 120
  • 6x2x0.5 10.3 52 143
  • 7x2x0.5 10.3 61 157
  • 8x2x0.5 11.4 70 183
  • 10x2x0.5 13.5 87 233
  • 2x2x0.75 8.1 26 77
  • 3x2x0.75 8.7 39 102
  • 4x2x0.75 9.6 52 129
  • 5x2x0.75 10.7 65 160
  • 6x2x0.75 11.7 78 190
  • 7x2x0.75 11.7 91 209
  • 8x2x0.75 12.9 104 244
  • 10x2x0.75 15.3 130 309
  • 2x2x1 8.5 35 89
  • 3x2x1 9.1 52 119
  • 4x2x1 10.2 69 155
  • 5x2x1 11.4 87 192
  • 6x2x1 12.5 104 228
  • 7x2x1 12.5 122 252
  • 8x2x1 13.7 139 293
  • 10x2x1 16.3 174 370
  • 2x2x1.5 10.3 52 132
  • 3x2x1.5 11.1 78 176
  • 4x2x1.5 12.3 104 227
  • 5x2x1.5 13.7 130 281
  • 6x2x1.5 15.1 156 332
  • 7x2x1.5 15.1 182 369
  • 8x2x1.5 16.6 208 427
  • 10x2x1.5 19.7 260 538