H07BZ5-F

SHARE

Product Certificates

You can click to download our certificates.

Areas of Use

The AC charging cable, which complies with EN 50620 and IEC 62893 standards, can be used in Mod1(single phase - domestic), Mod 2&3 (single/three phase - commercial/public) systems.They are designed for nominal voltages up to and including 450/750 V.The electric vehicle charging cable can be used safely in areas with high human density, open/closed garages, parking areas. They are also suitable for use in dry, damp or wet areas.

Cable Construction

  • Conductor Stranded Tinned Copper (Class 5)
  • Insulation Halogen Free Polymer (EVI-2) Shore A 81
  • Power Cores Identification HD 308 S2
  • CC & CP Cores Identification White Numbered Acc. to EN 50334
  • Lay-up Cores are stranded in layers (With Filler if Necessary)
  • Separator PET Foil
  • Outer Sheath TPU (EVM-1), RAL 9005 - Black
  • Reference Standards EN 50620 , IEC 62893-3

Technical Properties

  • Operating Voltage 450/750 V
  • Test Voltage 2.5 kV
  • Temperature Range Operating: -40°C...+90°C, Installation: -10°C...+80°C
  • Flame Retardancy IEC 60332-1-2
  • Smoke Density IEC 61034-1/2
  • Oil Resistance IRM 902 Acc. to EN 60811-404
  • Saponification Resistance EN 50396
  • Surface Resistance of Sheath EN 50395
  • N-oxalic Acid Resistance EN 60811-404
  • N-sodium hydroxide Resistance EN 60811-404
  • Ozone Resistance at Complete Cable EN 60811-404
  • UV Resistance EN 50289-4-17 Method A
  • Mechanical Strength EN 50396
  • Chemicals Resistance EN 50620 Annex D
  • Min. Bending Radius 6 x Cable Diameter